You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 144 No. 9, September 1984 TABLE OF CONTENTS
  Archives
  •  Online Features
  ORIGINAL INVESTIGATIONS
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Coronary Flow Reserve Measured During Cardiac Catheterization

Robert A. Vogel, MD; Eric R. Bates, MD; William W. O'Neill, MD; Fred M. Aueron, MD; Bernhard Meier, MD; Andreas R. Gruentzig, MD

Arch Intern Med. 1984;144(9):1773-1776.


Abstract

• The degree of arteriographically visualized narrowing in coronary arteries has been the most important criterion for evaluating coronary disease for more than 20 years. Increasing data, however, suggest that anatomy alone does not predict the physiologic consequence of individual stenoses. We have applied a new digital arteriographic method for measuring coronary flow reserve (CFR) in patients undergoing diagnostic, postbypass, and postangioplasty catheterizations. All vessels with high-grade stenoses (≥70%) were found to have lower CFRs than those of normal arteries (1.01 ± 0.15 v 1.84 ± 0.36). However, considerable CFR variability was found In vessels of lesser stenoses. Coronary arteries that had undergone successful bypass surgery or angioplasty had intermediate CFR levels (1.44 ± 0.18 and 1.51 ± 0.16, respectively). Our study suggests that CFR assessed during cardiac catheterization may be useful for evaluating intermediate coronary lesions and the efficacy of interventions.

(Arch Intern Med 1984;144:1773-1777)



Author Affiliations

From the Divisions of Cardiology, Veterans Administration Medical Center (Drs Vogel, Bates, and Aueron) and University Hospital (Dr O'Neill), University of Michigan, Ann Arbor; and the Division of Interventional Cardiovascular Medicine, Department of Medicine, Emory University Hospital, Atlanta (Drs Meier and Gruentzig).


Footnotes

Accepted for publication Jan 17,1984.

Reprint requests to the Division of Cardiology, Veterans Administration Medical Center, 2215 Fuller Rd, Ann Arbor, MI 48105 (Dr Vogel).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Coronary Artery Blood Flow: Measurement and Importance
Lancaster and Goldman
Arch Intern Med 1984;144:1742-1744.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1984 American Medical Association. All Rights Reserved.