You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


Advertisement

ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | RSS | Access Rights | Sign In


  Vol. 150 No. 11, November 1990 TABLE OF CONTENTS
  Online Only
 •  Online First Table of
Contents
  SPECIAL ARTICLE
 •Online Features
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (32)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Delicious Add to Digg Add to Facebook Add to Reddit Add to Technorati Add to Twitter What's this?

National High Blood Pressure Education Program Working Group Report on Ambulatory Blood Pressure Monitoring

The National High Blood Pressure Education Program Coordinating Committee

Arch Intern Med. 1990;150(11):2270-2280.


Abstract



• Blood pressure measurements obtained in a physician's office may not represent a patient's blood pressure during an entire day. Ambulatory blood pressure monitoring (ABPM) provides multiple readings over time. This review of the literature on ABPM addresses the current state of ABPM methods, normal blood pressure profiles, the clinical and research uses of ABPM, cost considerations, and recommendations for use of ABPM in selected circumstances. Current ABPM devices use either auscultatory or oscillometric methods to determine blood pressure. A rigorous comparison of these methods is needed to determine whether one method is more reliable. A nonbiased assessment of all available equipment is necessary. Normative data provided by ABPM research are needed for populations by age, race, gender, body habitus, and conditions, such as pregnancy. While ABPM is not cost-effective for all hypertensive patients, it can assist in the evaluation of such problems as target organ complications, syncopal episodes, episodic hypertension, and autonomic dysfunction.

(Arch Intern Med. 1990;150:2270-2280)



Author Affiliations



From the National High Blood Pressure Education Program, The National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Md.


Footnotes



Accepted for publication June 29,1990.

Reprint requests to National High Blood Pressure Education Program, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892 (Edward Roccella, PhD, MPH, Coordinator).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Delicious Delicious   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Assessment of the White-Coat Effect Among Hypertensive Patients Presumed to Be at Goal
Bookstaver and Hatzigeorgiou
The Annals of Pharmacotherapy 2011;45:910-915.
ABSTRACT | FULL TEXT  

Chapter 6 Diagnosis and investigations of hypertension
Nadar
OCL Hypertension 2009;1:med-9780199547579-chapter-med-9780199547579-chapter.
ABSTRACT | FULL TEXT  

Ambulatory Blood Pressure Monitoring in Children and Adolescents
Simckes et al.
CLIN PEDIATR 2002;41:549-564.
ABSTRACT  

Ambulatory Blood Pressure Monitoring and Diagnostic Errors in Hypertension: A Bayesian Approach
Mar et al.
Med Decis Making 1998;18:429-435.
ABSTRACT  

Antihypertensive Treatment Efficacy in Type II Diabetes Mellitus : Dissociation Between Casual and 24-Hour Ambulatory Blood Pressure
Puig et al.
Hypertension 1995;26:1093-1099.
ABSTRACT | FULL TEXT  

Does This Patient Have Hypertension? How to Measure Blood Pressure
Reeves
JAMA 1995;273:1211-1218.
ABSTRACT  

Ambulatory Blood Pressure Monitoring: Quality Assurance
Sheps
Arch Intern Med 1995;155:548-548.
ABSTRACT  

Clinical Utility of Ambulatory Blood Pressure Monitoring in the Evaluation of Patients with Borderline Hypertension
Waeber et al.
European Journal of Cardiovascular Prevention & Rehabilitation 1994;1:120-126.
ABSTRACT  

A Review of Common Errors in the Indirect Measurement of Blood Pressure: Sphygmomanometry
Bailey and Bauer
Arch Intern Med 1993;153:2741-2748.
ABSTRACT  

Hypertension: Steps Forward and Steps Backward: The Joint National Committee Fifth Report
Weber and Laragh
Arch Intern Med 1993;153:149-152.
ABSTRACT  

The Fifth Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure (JNC V)
Arch Intern Med 1993;153:154-183.
ABSTRACT  

Variability of Indirect Methods Used to Determine Blood Pressure: Office vs Mean 24-Hour Automated Blood Pressures
Bottini et al.
Arch Intern Med 1992;152:139-144.
ABSTRACT  