You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 152 No. 1, JANUARY 1992 TABLE OF CONTENTS
  Archives
  •  Online Features
  ORIGINAL INVESTIGATIONS
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (31)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Variability of Indirect Methods Used to Determine Blood Pressure

Office vs Mean 24-Hour Automated Blood Pressures

Peter B. Bottini, PharmD; Albert A. Carr, MD; Robert B. Rhoades, MD; L. Michael Prisant, MD

Arch Intern Med. 1992;152(1):139-144.


Abstract

Blood pressure is a cardiovascular measurement with dynamic characteristics that can be influenced by a number of internal and external factors. The preferred blood pressure determination method would be one that reduces variability between measurements and that reflects the true blood pressure level. In this article, we present the variability of, and agreement between, the blood pressures collected by two indirect methods on the same patients during a hypertensive research project. Data obtained on patients in a typical clinical setting are also provided. Twenty-four-hour diastolic pressures obtained by the automated method demonstrated no regression to a lower mean, while blood pressures obtained casually in the office exhibited such regression. The 95% confidence interval of repeated measures for casual office blood pressure on a patient in a research setting (35/17 mm Hg) or in typical clinic practice (26/19 mm Hg) were similar, while the range of the mean 24-hour automated blood pressure monitoring (21/11 mm Hg) was smaller and demonstrated less variability. The magnitudes of the differences in blood pressures obtained on separate occasions in the same subjects were significantly lower with automated vs casual blood pressure determination methods (7.9/4.6 vs 13.7/7.4 mm Hg for both systolic and diastolic pressures). The agreement (95% confidence interval) between blood pressures obtained by the two methods (19/12 mm Hg) was found to be similar to the repeatability of automated blood pressure monitoring alone, and superior to that for data recorded casually in the office (35/17 mm Hg). Thus, the variability in mean 24-hour automated blood pressures is less than that for casual office blood pressures. The clinician should understand that the variability of blood pressures measured on an individual may be much greater than that reported for populations of hypertensive patients, and must be considered when applying epidemiologic group data to a specific patient. Moreover, any methodology of indirect blood pressure measurement that may reduce the variability and improve repeatability of casual office blood pressures deserves further consideration.

(Arch Intern Med. 1992;152:139-144)



Author Affiliations

From the Section of Hypertensive and Vascular Diseases, Medical College of Georgia (Drs Bottini, Carr, and Prisant) and Medical Parameters Inc (Drs Bottini and Rhoades), Augusta, Ga.


Footnotes

Accepted for publication June 25, 1991.

Reprint requests to the Section of Hypertensive and Vascular Diseases, AF-2033, Department of Medicine, School of Medicine, Medical College of Georgia, Augusta, GA 30912-3150 (Dr Bottini).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Ambulatory Monitoring Detects Sorafenib-Induced Blood Pressure Elevations on the First Day of Treatment
Maitland et al.
Clin. Cancer Res. 2009;15:6250-6257.
ABSTRACT | FULL TEXT  

Reduction of ACE Activity Is Insufficient to Decrease Microalbuminuria in Normotensive Patients With Type 1 Diabetes
Bojestig et al.
Diabetes Care 2001;24:919-924.
ABSTRACT | FULL TEXT  

Prevalence and predictors of white-coat response in patients with treated hypertension
MacDonald et al.
CMAJ 1999;161:265-269.
ABSTRACT | FULL TEXT  

Blood Pressure Outcome of Angioplasty in Atherosclerotic Renal Artery Stenosis : A Randomized Trial
Plouin et al.
Hypertension 1998;31:823-829.
ABSTRACT | FULL TEXT  

Variability in Indirect Blood Pressure Measurement
Bottini and Carr
Arch Intern Med 1994;154:1536-1536.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1992 American Medical Association. All Rights Reserved.