You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 167 No. 7, April 9, 2007 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Investigation
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (12)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Bacterial Infections
 •Pacemakers/ Defibrillators
 •Cardiovascular System
 •Infectious Diseases
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Permanent Pacemaker and Implantable Cardioverter Defibrillator Infection

A Population-Based Study

Daniel Z. Uslan, MD; Muhammad R. Sohail, MD; Jennifer L. St. Sauver, PhD; Paul A. Friedman, MD; David L. Hayes, MD; Sarah M. Stoner, MS; Walter R. Wilson, MD; James M. Steckelberg, MD; Larry M. Baddour, MD

Arch Intern Med. 2007;167(7):669-675.

Background  The incidence of cardiac device infection is not well understood. Bloodstream infection (BSI) in patients with permanent pacemakers or implantable cardioverter-defibrillators (hereafter, defibrillators) may reflect device infection.

Methods  Retrospective, population-based cohort study of all adult patients with cardiac devices who resided in Olmsted County, Minnesota, from 1975 to 2004. The medical linkage-system of the Rochester Epidemiology Project and standardized criteria were used to identify all cases of BSI and device infection. The incidence of device infection was calculated with person-years of follow-up after device implantation.

Results  A total of 1524 patients with cardiac devices were included in the cohort. Total person-time of follow-up was 7578 years. The incidence of definite device infection was 1.9 per 1000 device-years (95% confidence interval [CI], 1.1-3.1). The incidence of pocket infection without BSI was 1.37 per 1000 device-years (95% CI, 0.62-3.05), and pocket infection with BSI or device-related endocarditis 1.14 per 1000 device years (95% CI, 0.47-2.74). The cumulative probability of device infection was higher among patients with defibrillators compared with those with pacemakers, P<.001. Twelve (54.6%) of 22 cases of Staphylococcus aureus BSI had definite or possible cardiac device infection vs 3 (12.0%) of 25 cases of bloodstream infection due to gram-negative bacilli (P = .004).

Conclusions  To our knowledge, this is the first population-based study to describe the incidence of cardiac device infection. Device infection was common during episodes of S aureus BSI. The rate of cardiac device infection was higher in patients with defibrillators than in those with pacemakers.


Author Affiliations: Department of Medicine, Divisions of Infectious Diseases (Drs Uslan, Wilson, Steckelberg, and Baddour) and Cardiovascular Diseases (Drs Friedman and Hayes), and Department of Health Sciences Research (Dr St. Sauver and Ms Stoner), Mayo Clinic College of Medicine, Rochester, Minn; and Division of Infectious Diseases, Department of Medicine, Tawam Hospital/Johns Hopkins Medicine, Al Ain, United Arab Emirates (Dr Sohail). Dr Uslan is now with the Division of Infectious Diseases, University of California, Los Angeles, David Geffen School of Medicine at UCLA.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Update on Cardiovascular Implantable Electronic Device Infections and Their Management: A Scientific Statement From the American Heart Association
Baddour et al.
Circulation 2010;121:458-477.
ABSTRACT | FULL TEXT  

Prevalence and risk factors related to infections of cardiac resynchronization therapy devices
Romeyer-Bouchard et al.
Eur Heart J 2010;31:203-210.
ABSTRACT | FULL TEXT  

Guidelines on the prevention, diagnosis, and treatment of infective endocarditis (new version 2009): The Task Force on the Prevention, Diagnosis, and Treatment of Infective Endocarditis of the European Society of Cardiology (ESC)
Endorsed by the European Society of Clinical Micro et al.
Eur Heart J 2009;30:2369-2413.
FULL TEXT  

Risk factors and time delay associated with cardiac device infections: Leiden device registry
Lekkerkerker et al.
Heart 2009;95:715-720.
ABSTRACT | FULL TEXT  

Non-sustained ventricular tachycardia as a predictor of sudden cardiac death in patients with left ventricular dysfunction: A meta-analysis
de Sousa et al.
Eur J Heart Fail 2008;10:1007-1014.
ABSTRACT | FULL TEXT  

High prevalence of asymptomatic bacterial colonization of rhythm management devices
Pichlmaier et al.
Europace 2008;10:1067-1072.
ABSTRACT | FULL TEXT  

Infective Endocarditis Complicating Permanent Pacemaker and Implantable Cardioverter-Defibrillator Infection
Sohail et al.
Mayo Clin Proc. 2008;83:46-53.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2007 American Medical Association. All Rights Reserved.