You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


Advertisement

ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | RSS | Access Rights | Sign In


  Vol. 167 No. 7, April 9, 2007 TABLE OF CONTENTS
  Online Only
 •  Online First Table of
Contents
  Original Investigation
 •Online Features
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (62)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Bacterial Infections
 •Pacemakers/ Defibrillators
 •Cardiovascular System
 •Infectious Diseases
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Delicious Add to Digg Add to Facebook Add to Reddit Add to Technorati Add to Twitter What's this?

Permanent Pacemaker and Implantable Cardioverter Defibrillator Infection

A Population-Based Study

Daniel Z. Uslan, MD; Muhammad R. Sohail, MD; Jennifer L. St. Sauver, PhD; Paul A. Friedman, MD; David L. Hayes, MD; Sarah M. Stoner, MS; Walter R. Wilson, MD; James M. Steckelberg, MD; Larry M. Baddour, MD

Arch Intern Med. 2007;167(7):669-675.

Background  The incidence of cardiac device infection is not well understood. Bloodstream infection (BSI) in patients with permanent pacemakers or implantable cardioverter-defibrillators (hereafter, defibrillators) may reflect device infection.

Methods  Retrospective, population-based cohort study of all adult patients with cardiac devices who resided in Olmsted County, Minnesota, from 1975 to 2004. The medical linkage-system of the Rochester Epidemiology Project and standardized criteria were used to identify all cases of BSI and device infection. The incidence of device infection was calculated with person-years of follow-up after device implantation.

Results  A total of 1524 patients with cardiac devices were included in the cohort. Total person-time of follow-up was 7578 years. The incidence of definite device infection was 1.9 per 1000 device-years (95% confidence interval [CI], 1.1-3.1). The incidence of pocket infection without BSI was 1.37 per 1000 device-years (95% CI, 0.62-3.05), and pocket infection with BSI or device-related endocarditis 1.14 per 1000 device years (95% CI, 0.47-2.74). The cumulative probability of device infection was higher among patients with defibrillators compared with those with pacemakers, P<.001. Twelve (54.6%) of 22 cases of Staphylococcus aureus BSI had definite or possible cardiac device infection vs 3 (12.0%) of 25 cases of bloodstream infection due to gram-negative bacilli (P = .004).

Conclusions  To our knowledge, this is the first population-based study to describe the incidence of cardiac device infection. Device infection was common during episodes of S aureus BSI. The rate of cardiac device infection was higher in patients with defibrillators than in those with pacemakers.


Author Affiliations: Department of Medicine, Divisions of Infectious Diseases (Drs Uslan, Wilson, Steckelberg, and Baddour) and Cardiovascular Diseases (Drs Friedman and Hayes), and Department of Health Sciences Research (Dr St. Sauver and Ms Stoner), Mayo Clinic College of Medicine, Rochester, Minn; and Division of Infectious Diseases, Department of Medicine, Tawam Hospital/Johns Hopkins Medicine, Al Ain, United Arab Emirates (Dr Sohail). Dr Uslan is now with the Division of Infectious Diseases, University of California, Los Angeles, David Geffen School of Medicine at UCLA.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Delicious Delicious   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

High-Dose Daptomycin for Cardiac Implantable Electronic Device-Related Infective Endocarditis
Durante-Mangoni et al.
Clinical Infectious Diseases 2012;54:347-354.
ABSTRACT | FULL TEXT  

Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper
Authors (EHRA Task Force Members) et al.
Europace 2012;14:124-134.
FULL TEXT  

Complete removal as a routine treatment for any cardiovascular implantable electronic device-associated infection
Pichlmaier et al.
J. Thorac. Cardiovasc. Surg. 2011;142:1482-1490.
ABSTRACT | FULL TEXT  

Anatomical factors involved in difficult cardiac resynchronization therapy procedure: a non-invasive study using dual-source 64-multi-slice computed tomography
Da Costa et al.
Europace 2011;0:eur350v1-eur350.
ABSTRACT | FULL TEXT  

16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United States: 1993 to 2008
Greenspon et al.
J Am Coll Cardiol 2011;58:1001-1006.
ABSTRACT | FULL TEXT  

Cardiovascular implantable electronic device infection: A complication of medical progress
SHRESTHA
Cleveland Clinic Journal of Medicine 2011;78:500-504.
FULL TEXT  

Cardiovascular implantable electronic device infection: A stepwise approach to diagnosis and management
DABABNEH and SOHAIL
Cleveland Clinic Journal of Medicine 2011;78:529-537.
ABSTRACT | FULL TEXT  

Use of a Simple Criteria Set for Guiding Echocardiography in Nosocomial Staphylococcus aureus Bacteremia
Kaasch et al.
Clinical Infectious Diseases 2011;53:1-9.
ABSTRACT | FULL TEXT  

Infection after pacemaker implantation: infection rates and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients
Johansen et al.
Eur Heart J 2011;32:991-998.
ABSTRACT | FULL TEXT  

A Summary of the Update on Cardiovascular Implantable Electronic Device Infections and Their Management: A Scientific Statement From the American Heart Association
Baddour et al.
Journal of the American Dental Association 2011;142:159-165.
ABSTRACT | FULL TEXT  

Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade Procedures: Results From the REPLACE Registry
Poole et al.
Circulation 2010;122:1553-1561.
ABSTRACT | FULL TEXT  

Treatment of patients with recurrent or persistent infection of cardiac implantable electronic devices
Knigina et al.
Europace 2010;12:1275-1281.
ABSTRACT | FULL TEXT  

Delayed cure from CIED infections: loosing only time without risk for patient outcome?
Wiegand
Europace 2010;12:1207-1208.
FULL TEXT  

Predictive factors of difficult implantation procedure in cardiac resynchronization therapy
Bisch et al.
Europace 2010;12:1141-1148.
ABSTRACT | FULL TEXT  

Recommendations for the practice of echocardiography in infective endocarditis
Habib et al.
Eur Heart J Cardiovasc Imaging 2010;11:202-219.
ABSTRACT | FULL TEXT  

Update on Cardiovascular Implantable Electronic Device Infections and Their Management: A Scientific Statement From the American Heart Association
Baddour et al.
Circulation 2010;121:458-477.
ABSTRACT | FULL TEXT  

Prevalence and risk factors related to infections of cardiac resynchronization therapy devices
Romeyer-Bouchard et al.
Eur Heart J 2010;31:203-210.
ABSTRACT | FULL TEXT  

The Value and Limitations of a Wound Inspection Clinic After Cardiac Device Implantation
Deuling et al.
Eur J Cardiovasc Nurs 2009;8:288-292.
ABSTRACT | FULL TEXT  

Guidelines on the prevention, diagnosis, and treatment of infective endocarditis (new version 2009): The Task Force on the Prevention, Diagnosis, and Treatment of Infective Endocarditis of the European Society of Cardiology (ESC)
Endorsed by the European Society of Clinical Micro et al.
Eur Heart J 2009;30:2369-2413.
FULL TEXT  

Risk factors and time delay associated with cardiac device infections: Leiden device registry
Lekkerkerker et al.
Heart 2009;95:715-720.
ABSTRACT | FULL TEXT  

Non-sustained ventricular tachycardia as a predictor of sudden cardiac death in patients with left ventricular dysfunction: A meta-analysis
de Sousa et al.
Eur J Heart Fail 2008;10:1007-1014.
ABSTRACT | FULL TEXT  

High prevalence of asymptomatic bacterial colonization of rhythm management devices
Pichlmaier et al.
Europace 2008;10:1067-1072.
ABSTRACT | FULL TEXT  

Risk Factor Analysis of Permanent Pacemaker Infection
Sohail et al.
Clinical Infectious Diseases 2007;45:166-173.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | PHYSICIAN JOBS | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 