You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 153 No. 17, 13 SEP 1993 TABLE OF CONTENTS
  Archives
  •  Online Features
  Editor's Correspondence
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

The Bedside Valsalva Maneuver: A Continually Overlooked Clinical Tool

Michael J. Zema, MD
East Patchogue, NY

Arch Intern Med. 1993;153(17):2055.

Since this article does not have an abstract, we have provided the first 150 words of the full text PDF and any section headings.

Although encouraged by this type of basic clinical investigation, I am disappointed to see the recent study by Marantz et al1 neglect to include the simple sphygmomanometrically determined systolic arterial pressure response as a criterion for the diagnosis of congestive heart failure. Marantz has previously2 demonstrated the utility of the bedside Valsalva maneuver in evaluating the acutely dyspneic patient. While the diagnosis of congestive heart failure has no "gold standard," we and others have found an unsurpassed correlation between the pattern of arterial pressure response detected by use of the bedside Valsalva maneuver and objectively documented left ventricular systolic3,4 and/or diastolic5,6 function. Use of the patient-performed Valsalva maneuver at the bedside during careful practitioner auscultation of the brachial systolic arterial pressure requires merely a stethoscope, sphygmomanometer, and 30 seconds of time. Ease of determination, lack of need for specialized equipment, objectively measurable end points,5 semi-quantitative . . . [Full Text PDF of this Article]



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1993 American Medical Association. All Rights Reserved.